Quantity
|
Out of stock
|
||
|
|
|||
|
|
|||
Corrugated electrical conduit 2325/LPE-1_F50DU Ø25 mm is designed for the protection and routing of electrical, telecommunication, network and low-voltage cables. It is made of polyethylene (PE), is halogen-free and features UV resistance, making it suitable for outdoor installation and use in areas exposed to sunlight.
The conduit has an outer diameter of 25 mm and a minimum inner diameter of 18.3 mm. Its flexible construction makes it easier to route cable lines with bends and changes of direction, while the supplied pull wire simplifies cable insertion and reduces installation time.
Mechanical resistance is rated at 320 N/5 cm. The wide operating temperature range of -25 to +90 °C allows the conduit to be used in various environmental conditions.
Advantages of the 2325/LPE-1_F50DU Corrugated Conduit
- UV-resistant design — suitable for outdoor installation.
- Made of durable PE (polyethylene).
- Halogen-free material.
- Pull wire included for easier cable installation.
- Outer diameter — 25 mm.
- Minimum inner diameter — 18.3 mm.
- Mechanical resistance — 320 N/5 cm.
- Operating temperature — -25 to +90 °C.
- Flexible construction for convenient cable routing.
- Coil length — 50 m.
- Suitable for electrical and low-voltage cable systems.
Technical Specifications
- Type: flexible corrugated electrical conduit
- Model: 2325/LPE-1_F50DU
- Material: PE (polyethylene)
- Halogen-free: yes
- Colour: black
- UV resistance: yes
- Outer diameter: 25 mm
- Inner diameter (min.): 18.3 mm
- Length: 50 m
- Length tolerance: ±1%
- Weight: 0.07 kg/m
- Mechanical resistance: 320 N/5 cm
- Operating temperature: -25 to +90 °C
- Reaction to fire of the base material: A1
- Classification code: 22423
- Standard: ČSN EN 61386-1 ed.2
- EAN: 8595057699366
- Customs code: 39173100
- Packaging: supplied with pull wire
Applications
The 2325/LPE-1_F50DU corrugated conduit can be used for protecting and routing:
- power cables;
- lighting cables;
- network and twisted-pair cables;
- telecommunication lines;
- CCTV system cables;
- alarm and security system cables;
- other low-voltage cable systems.
Thanks to its UV resistance, the conduit is suitable for outdoor cable routing in areas where prolonged exposure to sunlight is possible.
Installation Recommendations
The manufacturer recommends installing plastic conduits at ambient temperatures above 0 °C. After installation, the permissible operating temperature range is -25 to +90 °C.
Corrugated electrical conduit 2325/LPE-1_F50DU Ø25 mm, 50 m is a practical solution for creating protected cable routes both indoors and outdoors. UV-resistant halogen-free PE, a wide operating temperature range, flexible construction and the integrated pull wire provide convenient installation and reliable cable protection.